CLAB-ANI-DEV-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF SnmpAdminString FROM SNMP-FRAMEWORK-MIB DateAndTime, TruthValue FROM SNMPv2-TC clabCommonMibs FROM CLAB-DEF-MIB; clabAniDevMib MODULE-IDENTITY LAST-UPDATED "201704270000Z" -- April 27, 2017 ORGANIZATION "Cable Television Laboratories, Inc." CONTACT-INFO "Broadband Network Services Cable Television Laboratories, Inc. 858 Coal Creek Circle, Louisville, CO 80027, USA Phone: +1 303-661-9100 Email: mibs@cablelabs.com" DESCRIPTION "This MIB module contains the management objects for sRouter devices under the CableLabs Access Network Independent (ANI) project. Copyright 1999-2017 Cable Television Laboratories, Inc. All rights reserved." REVISION "201704270000Z" -- April 27, 2017 DESCRIPTION "Modified per ECN CLAB-ANI-DEV-MIB-N-17.0160-1." REVISION "201702210000Z" -- February 21, 2017 DESCRIPTION "Corrected capitalization of one instance of AniDevSysLoggingGrpCtrl. Logging was inadvertently lower case. No EC required." REVISION "201605190000Z" -- May 19, 2016 DESCRIPTION "Added System Event logging objects per sRouter-N-16.0147-2." REVISION "201603170000Z" -- March 17, 2016 DESCRIPTION "Initial version, published as part of the CableLabs Standalone Router Specification, CL-SP-sRouter-I01-160317. Copyright 2016 Cable Television Laboratories, Inc. All rights reserved." ::= { clabCommonMibs 7 } -- Object Definitions clabAniDevObjects OBJECT IDENTIFIER ::= { clabAniDevMib 1 } aniDevResetNow OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to true(1) causes the device to reset. Reading this object always returns false(2)." ::= { clabAniDevObjects 1 } clabAniDevSysLoggingObjects OBJECT IDENTIFIER ::= { clabAniDevObjects 2 } aniDevLoggingCtrlReset OBJECT-TYPE SYNTAX INTEGER { resetLog(1), pauseLog(2), startLog(3), useDefaultReporting(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to resetLog(1) empties the logging table. Setting this object to pauseLog(2) causes the ANI device to stop writing events to the logging table. Setting this object to startLog(3) causes the ANI device to start writing events to the logging table. Reading this object returns either pauseLog(2) or startLog(3). The default is startLog(3). Log event pausing is independent of any other log filtering mechanisms, e.g., levels. Setting it to useDefaultReporting(4) resets the log (i.e., empties) and returns all event levels to the factory-default reporting." ::= { clabAniDevSysLoggingObjects 1 } aniDevSysLoggingSize OBJECT-TYPE SYNTAX Unsigned32 UNITS "bytes" MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object modifies the size of the system logging table. When set to zero, all entries are removed and new entries are not allowed to be added. When set less than the current size, the oldest entries are removed until the new size is reached." ::= { clabAniDevSysLoggingObjects 2 } -- -- The following Object controls the reporting of the various classes -- of system log messages. -- aniDevSysLoggingLevelCtrl OBJECT-TYPE SYNTAX INTEGER { all(1), trace(2), debug(3), info(4), warn(5), error(6), fatal(7), off(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "The current logging priority level for system messages. Setting a level sets all levels from the level specified to the highest severity level except for “off”. The level “all” indicates all levels. The log levels are derived from the log4j class. all(1) The all level has the lowest possible rank and is intended to turn on all logging. trace(2) The trace level designates finer-grained informational events than the DEBUG (see log4j class for further definition). debug(3) The debug level designates fine-grained informational events that are most useful to debug an application. info(4) The info level designates informational messages that highlight the progress of the application at coarse-grained level. warn(5) The warn level designates potentially harmful situations. error(6) The error level designates error events that might still allow the application to continue running. fatal(7) The fatal level designates very severe error events that will presumably lead the application to abort. off(8) The off has the highest possible rank and is intended to turn off logging." ::= { clabAniDevSysLoggingObjects 3 } aniDevSysLoggingGroupCtrl OBJECT-TYPE SYNTAX BITS { none(0), all(1), group1(2), group2(3), group3(4), group4(5), group5(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "The system 'group' or 'groups' to be logged. If all(1) is set, then other bits are ignored. If set to 'none(0)', messages that do not include a 'group' are candidates to be logged. Logging Groups for Event Logs are defined in the controlling Access Network Independent device specification for equipment implementing this MIB. Returns WrongValue error if an attempt is made to set the bit for a Logging Group not supported by the device." DEFVAL {{ none }} ::= { clabAniDevSysLoggingObjects 4 } -- The ANI Device System Logging table. -- -- This table is used as an event logging table shared by the system -- and applications. Note that network-related events are still -- recorded in the aniDevSysLoggingEventTable. The ANI device adds an -- event by adding a conceptual row to the end of the table. -- Once the table 'fills' by reaching aniDevSysLoggingSize, adding a -- new event causes the oldest conceptual row to be removed. -- aniDevSysLoggingEventTable OBJECT-TYPE SYNTAX SEQUENCE OF AniDevSysLoggingEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is a cyclic table of events." ::= { clabAniDevSysLoggingObjects 5 } aniDevSysLoggingEventEntry OBJECT-TYPE SYNTAX AniDevSysLoggingEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A logging event entry." INDEX { aniDevSysLoggingEventIndex } ::= { aniDevSysLoggingEventTable 1 } AniDevSysLoggingEventEntry::= SEQUENCE { aniDevSysLoggingEventIndex Unsigned32, aniDevSysLoggingEventTimeStamp DateAndTime, aniDevSysLoggingEventMessage SnmpAdminString } aniDevSysLoggingEventIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Provides relative ordering of the objects in the event log. This object will always increase except when (a) the log is reset via aniDevSysLoggingEventCtrlReset or (b) the device reboots and does not implement non-volatile storage for this log. The next entry for all the above cases is 1." ::= { aniDevSysLoggingEventEntry 1 } aniDevSysLoggingEventTimeStamp OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The time stamp of this event logging entry. The timestamp is established when the event occurs." ::= { aniDevSysLoggingEventEntry 2 } aniDevSysLoggingEventMessage OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The event message." ::= { aniDevSysLoggingEventEntry 3 } -- Conformance Definitions clabAniDevConformance OBJECT IDENTIFIER ::= { clabAniDevMib 2 } clabAniDevCompliances OBJECT IDENTIFIER ::= { clabAniDevConformance 1 } clabAniDevGroups OBJECT IDENTIFIER ::= { clabAniDevConformance 2 } clabAniDevCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for CableLabs ANI devices." MODULE --- clabAni MANDATORY-GROUPS { clabAniDevGroup } ::= { clabAniDevCompliances 1 } clabAniDevGroup OBJECT-GROUP OBJECTS { aniDevResetNow, aniDevLoggingCtrlReset, aniDevSysLoggingSize, aniDevSysLoggingLevelCtrl, aniDevSysLoggingGroupCtrl, aniDevSysLoggingEventTimeStamp, aniDevSysLoggingEventMessage } STATUS current DESCRIPTION "Object(s) implemented for the management of ANI devices." ::= { clabAniDevGroups 1 } END